Apparatus and method for acquisition of tomographic images by microwave

Benefits
Why choose this technology
The strengths of this technology.
Cost from 10 to 1000 times lower than classic MRI equipment.
Operating cost in electricity consumption from 10 to 200 times lower.
Operational footprint that does not require dedicated environments.
Diagnosis time
About 1 minute to get the pictures.
Possibility of use in small medical offices for first-level diagnostics.
Technology
How it works
The invention consists of an apparatus and method for the detection of first-level tumour masses, pleural effusions and cysts, using electromagnetic waves in the microwave spectrum, with the advantage of speed of diagnosis of pathologies over classical techniques.
The instrument takes the form of a torus, similar to existing TAC and MRI machines, but much more compact and much lighter due to its internal structure. Several antennas capable of receiving and transmitting EM waves are contained within the torus.
The detection is carried out by varying the emission frequency of EM waves and revealing both the parameters of the waves transmitted by each antenna to all the others, and the parameters of the waves reflected by an antenna to itself. With this procedure the system extracts the dielectric parameters of the medium in which the waves propagate, identifying in particular any net variation of the same. These net variations are synonymous with barriers, membranes or variations in the composition of an organic tissue compared to another adjacent one, which makes it possible to easily identify cysts and/or tumors.
Are you interested in this technology?
Ask us for availability, license terms or more detailed technical material. The TT Service answers you.
Applications
Where this technology is applied
The areas in which this technology offers the greatest advantage.
Tomographic imaging
Cancer screening
Explore
Other technologies in Medical Devices and Sensors

- Medical devices and sensors
Detector for measuring a beam of ionising radiation
The patented technology refers to detection systems for monitoring and controlling the radiation dose delivered on the...

- Diagnostics and Imaging
Intraoperative probe for detection of tumour residues
The intraoperative probe is able to locate, at the operating site, tumor residues marked with appropriate beta-emitting radiopharmaceuticals. Making it simpler...

- Medical devices and sensors
Hard X-ray concentrator for radiotherapy
The invention concerns an X-ray concentrator that can be used in the 10-1000 keV energy range. Used in combination with an X-ray tube or other...
Contact us
Can this technology help your business?
Tell us about your project: the TT Service puts you in touch with the researchers who have developed the technology and evaluates with you the most suitable form of collaboration.
Contact the TT Service