{"id":5692,"date":"2026-07-16T10:00:00","date_gmt":"2026-07-16T08:00:00","guid":{"rendered":"https:\/\/web.infn.it\/TechTransfer\/?p=5692"},"modified":"2026-07-16T10:00:00","modified_gmt":"2026-07-16T08:00:00","slug":"cbct","status":"publish","type":"post","link":"https:\/\/infndev.laserromae.it\/en\/cbct\/","title":{"rendered":"New frontiers in X-ray computed tomography for patient diagnosis and treatment"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">Antonio Sarno, researcher of the INFN section in Milan, works to make X-ray tomography with a conical beam more and more accurate.<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">In search of accuracy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">How can we improve the quality of the images obtained for <strong>CBCT<\/strong> (Cone Beam Computed Tomography), extending its use to fields where it is not yet widely used? This is the challenge that the group of <strong>Antonio Sarno<\/strong>, at the <strong><a href=\"https:\/\/www.mi.infn.it\/it\/\">INFN section of Milan<\/a><\/strong>, wants to overcome.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2018compared to traditional tomography, CBCT has some advantages\u2019, says Sarno, \u2018first of all the fact that, using a conical beam, the creation of the 3D image takes place by having the X-ray source travel a single turn around the part to be analysed, unlike traditional computed tomography (CT) scans in which the source moves with a helix around the patient. This saves time and reduces costs, both in economic terms and in terms of dose to the patient.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, there is a limit to image quality: a beam opening cone-shaped increases diffuse radiation, causing artifacts and a reduction in the noise signal ratio. The scanning geometry then, which limits the source to rotate in a fixed plane, allows the accurate reconstruction of only the central plane of the image. These limitations allow CBCT to be used only as a method of analysis <strong>anatomical \u2013 qualitative: <\/strong>It is possible to reconstruct the shape of organs in 3D, but the quantitative information extracted is affected by poor accuracy and precision.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Towards a Quantitative CBCT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The qualitative nature of CBCT images reduces their field of use. In radiotherapy, for example, it is possible to use it to align treatment plans: before a radiotherapy session a scan is carried out on the patient to reposition the beam on the tumor target, but it is not currently used to reshape the treatment plan on any anatomical changes that have occurred in the patient. It is used in pre-surgical verification to identify the treatment site and for post-clearance verification, but it cannot accurately verify the physical characteristics of the implant site, nor accurately verify the position of a prosthesis, particularly in the case of the presence of metal components. Diffuse radiation and the reduction of conspicuity at the edges can prevent the detection and characterization of small details that are fundamental for diagnosis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The work of Sarno's group lies precisely in the <strong>make CBCT images quantitative <\/strong>and thus overcome the paradigms in the use of CBCT, which to date have been linked to a qualitative use. The innovative idea, which generated <strong>two patents<\/strong> to date held by INFN, is based on exceeding the circular scanning orbit: each tomographic projection is divided into several narrower projections acquired on a sinusoidal scanning orbit. Reducing projection extent reduces diffuse radiation, and sinusoidal orbit compensates for field reduction on the one hand, and mitigates conspicuity limitation due to conventional circular orbit on the other.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cThis effect can be achieved by physically moving the source, or by electronically switching on and off a multi-anode source, or capable of producing X-rays from multiple positions, as if it incorporated a multiplicity of conventional sources\u201d, explains Sarno, \u201cthere are advantages and disadvantages in each solution, we have patented both. The final effect is that images of better quality and with minimal artifacts are obtained, which can then be used for quantitative measurements.\u201d Of particular interest is the use of multi-anode sources, which represent one of the greatest innovations in compact X-ray production in recent years, and may be a milestone in radiodiagnostics in the near future.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The next step: Functional CBCT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\"There is, however, a subsequent step we are working on\", continues Sarno, \"tomographies, both standard and CBCT, produce images whose contents provide us with morphological-anatomical information about the patient, but are not able to provide us with information about the functional state of the tissues. To overcome this paradigm, we are developing innovative contrast agents, which once injected into the patient can target particular tissues, such as certain types of breast or pancreatic cancers, and then be \u2018traced\u2019 through a quantitative tomographic examination. Obviously, alongside the development of such law enforcement tools, there is the development of a number of hardware and software technologies, as well as physical methodologies for such tracking.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is why the project was born <strong>CIRCE<\/strong>, which sees the participation of INFN and the University of Milan and the collaboration with the Institute of Chemical Sciences and Technologies \u201cGiulio Natta\u201d of the CNR and the IRCCS Humanitas of Rozzano, whose aim is to develop new contrast agents based on <strong>hafnium oxide (HfO) nanoparticles<sub>2<\/sub>)<\/strong> <strong>functionalised<\/strong> which are preferentially linked to areas of the organ affected by particular pathologies. In this way the CBCT could also acquire the ability of functional analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This technology also has <strong>applications outside medical use<\/strong>, for example for the verification of prototypes and industrial artefacts and 3D scanning of baggage at airports, or for cargo inspection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The traditional baggage scanning system involves capturing two-dimensional radiological images. The recent introduction of CBCT systems allows 3D reconstruction of luggage contents for a more thorough inspection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\"My dream is to open the laboratory to third parties\", concludes Sarno, \"so as to allow users and industries to test our technologies and, hopefully, to establish collaborative relationships with INFN to exploit them commercially. For this purpose, the help and support of the Technology Transfer Service is essential.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Find out more<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you are interested in CBCT technology and patents filed by INFN, you can contact the <a href=\"mailto:tto@lists.infn.it\">Technology Transfer Service<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You can consult the cards of the two patents on CBCT <a href=\"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/\" target=\"_blank\" rel=\"noreferrer noopener\">here<\/a> e <a href=\"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-cone-beam-ct-per-uso-quantitativo\/\" target=\"_blank\" rel=\"noreferrer noopener\">here<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Antonio Sarno, researcher of the INFN section in Milan, works to make X-ray tomography with a conical beam more and more accurate.<\/p>","protected":false},"author":2,"featured_media":5705,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[658],"tags":[511,561,565],"class_list":["post-5692","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tecnologie","tag-cbct","tag-raggi-x","tag-scienze-della-vita"],"acf":[],"_links":{"self":[{"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/posts\/5692","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/comments?post=5692"}],"version-history":[{"count":0,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/posts\/5692\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/media\/5705"}],"wp:attachment":[{"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/media?parent=5692"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/categories?post=5692"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/infndev.laserromae.it\/en\/wp-json\/wp\/v2\/tags?post=5692"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}